Understanding error messages at the filling station
The fill assistant tells you what’s wrong whenever there’s a problem. Here you’ll find all the messages with their cause and solution. For most of them, a quick check and a tap on “Try again” is all it takes.
During the pressure test (tank connected, valve closed)
“The required pressure was not reached”
Cause: Air is escaping at the connection – usually a dirty or damaged O-ring or a handwheel that isn’t tightened firmly enough.
Solution: Check the O-ring, tighten the handwheel firmly, tap “Try again”.
“The system doesn’t seem to be fully sealed”
Cause: The tank isn’t seated correctly on the fill hose.
Solution: Unscrew the tank, reattach it straight, tighten firmly, tap “Try again”.
When opening the tank
“No pressure drop measured”
Cause: The tank valve isn’t fully open – or the tank is already full.
Solution: Open the valve fully, tap “Try again”. If it is open, the tank is full: topping up only works from approx. 10 bar below the final pressure – see Topping up your tank.
“The tank pressure is below the minimum residual pressure of 10 bar”
Cause: The tank is (almost) empty – moisture may have got into it.
Solution: Can’t be filled. Tap “Stop” and have the tank checked by a specialist dealer.
During the fill
“The maximum fill time has been reached”
Cause: Safety limit – a fill runs for a maximum of 10 minutes (older stations 5 minutes).
Solution: Close the tank; with “Fill another tank” you can carry on filling straight away.
“The pressure in the tank dropped during filling”
Cause: A leak at the connection or the tank.
Solution: Close the tank, check the connection and tank, and only then start again.
“The storage pressure has fallen below the required threshold”
Cause: The station’s air storage has just been drawn down by filling – shown in yellow on the map.
Solution: Close the tank and carry on filling later. If the compressor is running, air will be available again soon.
“Your credit has run out”
Solution: Close the tank, top up your credit, start again. You’ll never be charged more than your credit.
While releasing pressure
“The tank doesn’t seem to be closed”
Solution: Turn the tank valve fully closed, tap “Try again”. Only unscrew after venting.
At any time
“The red emergency stop button is pressed”
Solution: Release the button by turning it, tap “Try again”. As long as it is pressed, filling is not possible.
“The station did not respond”
Cause: The station is briefly unreachable.
Solution: Tap “Try again”. If the problem persists: check the marker on the map (red = malfunction), close the tank and let us know.
“Connection lost – reconnecting automatically”
Cause: Your phone briefly has no signal. A running fill continues.
Solution: Do nothing – the page reconnects by itself.
“Filling finished – your phone hasn’t responded for a while”
Solution: Close the tank valve, then press the red emergency stop – the station vents the hose. Release the button again; you can start again at any time.
Frequently asked questions
Am I still charged if there’s an error?
You’re only charged for the litres the station actually filled. If a pressure test is aborted, there are no costs.
What if a message keeps coming back?
Close the tank, check the station’s marker and get in touch via the contact form – ideally with the message and the time.
Can I cancel the process at any time?
Yes, with “Stop”. Outside the fill, the station then vents the fill hose – close your tank valve first.
Filling your own dive tank – here’s howYour first fill – checklistWhich tank is right for you? 200, 232 or 300 barTopping up your tankTransporting and storing dive tanksFilling nitrox yourselfHow clean is the breathing air?Your own self-service filling station Checking your tank inspection (TÜV) FAQ